Check O-ring seals for proper seating in grooves - arrows  - on respective mount.

-

Check the fitting pin - A - (not installed on all connections) and refrigerant line connections - B - -  E - and - F - for damage and proper seating.

-

Tighten the screws - D -.

‹› Tightening specification: 9 Nm.

-

Install the cover on the lock carrier. 

-

Evacuate and fill the refrigerant circuit. Refer to => Refrigerant R134a - Servicing.

-

Install the remaining components.

-

Check Diagnostic Trouble Code (DTC) memory of A/C control head climatronic control module (J255) and erase any displayed malfunction if
necessary. Refer to => Vehicle Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

-

Operate the A/C system after filling the refrigerant circuit. Refer to => [ A/C System, Operating after Filling Refrigerant Circuit ] See: Heating and
Air Conditioning/Service and Repair/Procedures/A/C System, Operating after Filling Refrigerant Circuit.

‹› Note the information regarding operating the A/C system after filling. Refer to => Refrigerant R134a - Servicing. 