Pivot the data bus on board diagnostic interface (J533) - item 3 - out of the bracket -  arrow -.

-

Disconnect the electrical connector - 4 -.

-

Disconnect the fiber optic cable connector - 1 -. 

-

Seal open wiring harness fiber optic connector - 2 - with Wiring Harness Connector Protective Cap (VAS 6223/9) -  item 1 -.

‹› Protective cap prevents contamination of or mechanical damage to end face of fiber optic cable which would impair signal transmission.

Installing

‹› Tightening specification. Refer to => [ Instrument Cluster RF Controlled Clock Receiver Assembly Overview ] See: Instrument Panel, Gauges and

Warning Indicators/Instrument Cluster / Carrier/Service and Repair/Instrument Cluster RF Controlled Clock Receiver Assembly Overview. 

Install in reverse order of removal, observing the following:

-

Install glove compartment.

-

Follow the instructions on the (VAS 5051B) display with a new Data Bus on board diagnostic interface (J533 ).