audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Pressure Test|Page 4902 > < Fuel Pressure Test|Page 4900
Page 5
background image

-

Connect an assisting hose - arrow - to pressure gauge and hold it in a measuring container.

-

Open shut-off valve of pressure gauge.

‹› The lever points in the direction of flow.

-

Bleed fuel system by pressing remote control briefly.

-

Close shut-off valve of pressure gauge.

‹› Lever stands perpendicular to direction of flow - arrow -. 

-

Hold the switch of the remote control until no more pressure increase is observed on the fuel pressure gauge.

‹› Specified value: Approximately 5.5 bar (4.5 to 6.5 bar) positive pressure. 

If specification is not obtained:

-

Check delivery quantity of Fuel Pump (FP).

Residual Pressure, Checking

-

Check for leaks and residual pressure by observing pressure drop on pressure gauge.

‹› After 10 minutes there must be a residual pressure of at least 3 bar. 

If residual pressure drops below 3 bar:

‹› Check connection between fuel pressure gauge and fuel line for leaks. 

Fuel Pressure Test|Page 4902 > < Fuel Pressure Test|Page 4900