Q5 Quattro V6-3.2L (CALB) (2009)
Transmission Cooler: Procedures
ATF Lines and Cooler, Cleaning
Special tools, testers and auxiliary items required
‹› Oil Collecting and Extracting Device (V.A.G 1782 )
‹› Hose dia. approximately 18 mm
‹› Compressed air gun, commercially available
‹› Protective glasses
Procedure
‹› Rules for cleanliness when working on the DSG transmission. Refer to => [ Clean Working Conditions ] See: Service Precautions/0B5A
Transmission/Clean Working Conditions.
CAUTION!
Danger of eye injury.
‹› Wear protective goggles!
-
Before installing a replacement transmission, always replace the ATF filter and ATF lines as well as the ATF cooler using compressed air
(maximum 10 bar).
‹› If extremely dirty ATF flows out when cleaning using compressed air, flush the ATF cooler and lines using clean ATF.