Hold measuring device for distance measurement - 2 - flush into angle bracket on one side of calibration platform as shown in illustration,
measuring unit must make contact firmly on angle bracket when doing this. 

-

Make sure that laser beam from measuring unit for distance measurement impinges paddle - 1 - at lower, enlarged part.

If this is not the case, paddles must be corrected accordingly via clamping screws on the wheel pick-ups.

-

Hold the measuring unit for distance measurement firmly by the hand in the angle bracket on the calibration platform while the laser beam can be
seen on the paddle.

-

Now press the ON button briefly for the distance measurement.

Display readout