Q7 Quattro V6-3.6L (BHK) (2007)
-
Disconnect electrical connector - 3 - for Engine Coolant Temperature (ECT) sensor (G62).
-
Remove bolts on connecting pieces - arrows - and remove clamp - 1 -.
-
Remove connecting pieces - 2 - - lower arrow - by pressing coolant pipe - 1 - in direction of coolant pump - upper arrow - with a pry bar.
-
Free up electrical connector - 1 - for Engine Speed (RPM) sensor (G28) on oil dipstick guide tube.
-
Free up B+ wire - arrow - on oil dipstick guide tube.
-
Remove bolt - 2 - and remove oil dipstick guide tube.
-
Unclip Intake Manifold Runner Control (IMRC) valve (N316) - arrow - from bracket and move upward slightly with lines connected.