audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Coolant Pump (V50)|Page 6177 > < Coolant Pump (V50)
Page 2
background image

-

Mark the arrangement of coolant hoses - D - (supply to heater core) and - C - (supply to engine).

-

Clamp off coolant hose to heater core - B - (e.g. using hose clamps up to 25 mm dia. (3094)).

-

Disconnect connector - A - from Coolant Pump (V50).

-

Remove bolts - F - and - G -.

-

Clamp off coolant hose (from engine) - C - (e.g. using hose clamps up to 25 mm dia. (3094)).

‹› If coolant hose - C - (different versions) should be too short to clamp, seal it e.g. using a sealing plug after disconnecting. 

-

Disconnect coolant hoses - C - and - D - from Coolant Pump (V50).

-

Remove Coolant Pump (V50) -  E -.

Installing

Installation is the reverse of removal, noting the following:

‹› With a discharged coolant circuit, a new Coolant Pump (V50) - E - must only be brought into operation only after the coolant circuit has been

charged, dry-running a pump may destroy it.

‹› Since only a small amount of coolant flowed out of coolant circuit when removing Coolant Pump (V50) - E - as described above, coolant flows

immediately into Coolant Pump (V50) after installing and removing the hose clamps and there is no danger of dry-running the pump.

-

Connect 2-pin harness connector - A - to pump only after removing the hose clamps.

-

Re-install the remaining removed components.

-

Bleed coolant circuit => [ Cooling Circuit, Bleeding ] See: Heating and Air Conditioning/Service and Repair/Procedures/Cooling Circuit,
Bleeding.

-

Add coolant if necessary. 

Coolant Pump (V50)|Page 6177 > < Coolant Pump (V50)