Page 1
background image

Hose/Line HVAC: Service and Repair
Refrigerant Line Connection Points

Refrigerant Line Connection Points

‹› The procedure for loosening applies to all connection points in the refrigerant circuit and for the branching point of refrigerant lines to rear heating

& A/C unit. There are differences in diameter for line connections, versions of O-ring seals and mounting bolts.

‹› Depending on component location, various components in vicinity of connection points must be loosened or removed to be able to disconnect the

connection point.

‹› The following illustration shows a connection point on plenum chamber front wall in engine compartment.

Disassembling

-

Discharge A/C refrigerant system.

-

Remove bolts - A -.

-

Disconnect connection points of refrigerant lines - D - and -  E -.

‹› Seal open connections of lines with suitable sealing caps (against penetration of dirt and moisture).

Assembling

Assembly is performed in the reverse order of removal, noting the following:

-

Replace O-ring seals - B - and - C -.

‹› Coat O-ring seals lightly with refrigerant oil before installing => [ O-Ring Seals for Refrigerant Circuit ] See: Heating and Air

Conditioning/Service and Repair/Removal and Replacement/O-Ring Seals for Refrigerant Circuit.

‹› Note the different tightening torques of bolts - A -. 

‹› Tightening torque of bolts - A - with a thread " M6" 10 Nm.

‹› Tightening torque of bolts - A - with a thread " M8" 20 Nm.

-

Check positions of refrigerant lines, they must be fully engaged in bracket and cannot come in contact with other components.

-

Reinstall any removed components or re-secure loosened components. 

-

Evacuate refrigerant circuit and recharge again.