Fuse Block: Service and Repair
Center Instrument Panel Relay and Fuse Carrier

Center Instrument Panel Relay and Fuse Carrier

Removing

-

Remove driver's side upper instrument panel cover.

-

Release retaining clips - 1 - and - 3 - and pivot center instrument panel relay and fuse carrier - 2 -down out of retaining frame - arrow -.

-

Remove relay or control modules, then unclip respective relay carrier. 

-

Release retaining clips - arrow - and press fuse holder - 1 - back out of relay and fuse carrier.

‹› Precise assignment of center instrument panel relay and fuse carrier can be seen from appropriate wiring diagram.

Installing

Install in reverse order of removal, observing the following:

-

Engage center instrument panel relay and fuse carrier in retaining frame.

-

Install driver's side upper instrument panel cover.