audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

All Other Service Bulletins for Power Distribution Module:|240851|Page 12384 > < All Other Service Bulletins for Power Distribution Module:|240851|Page 12382
Page 1
background image

PROM - Programmable Read Only Memory: All Technical Service Bulletins
Engine Controls - MIL ON/Camshaft Adjuster DTC's Set

24 08 52 

2014775/2 

November 18, 2008. Supersedes Technical Service Bulletin Group 24 number 07-12 dated July 10, 2007 for reasons listed below.

Vehicle Information

01 MIL on (DTCs for camshaft adjustment in ECM)

Condition

The customer may report:

-

Engine may run rough.

-

The MIL may be on, and one or more of the following DTCs are present in the ECM data memory:

P000A

Bank 1, Intake, Camshaft adjustment slow response

P000B

Bank 1, Exhaust, Camshaft adjustment slow response

P000C

Bank 2, Intake, Camshaft adjustment slow response

P000D

Bank 2, Exhaust, Camshaft adjustment slow response

P0011

A Camshaft Position (Bank 1)

Timing over-advanced or System Performance

P0014

B Camshaft Position (Bank 1)

Timing over-advanced or System Performance

P0017

Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor B

Technical Background

NOTE:  

Any Update Programming procedure (flash) may overwrite any tuned ECM or TCM programming. A tuned ECM or TCM is described as any ECM
or TCM altered so as to perform outside the normal parameters and specifications approved by Audi of America, Inc.

Current Tuned ECM or TCM Requirements

If you encounter a vehicle with a tuned ECM or TCM, your dealership must do the following before performing any procedure that updates ECM or
TCM programming:

-

Notify the owner that their ECM or TCM was found to have been tuned.

-

Notify the owner that any damage caused by the tuning of the ECM or TCM (including any adverse emissions consequences) will not be covered
by Audi of America, Inc. warranties.

All Other Service Bulletins for Power Distribution Module:|240851|Page 12384 > < All Other Service Bulletins for Power Distribution Module:|240851|Page 12382