Close Pliers For Fibre-optic Conductor VAS6223/1.

-

Secure hex socket screw - arrow - for transportation safeguard on blade.

Attaching brass pin contact to fiber optic cable 

-

Open securing lever on Crimping Pliers For Fiber-optic Cable VAS6223/2 - arrow 1 - and - arrow 2 -.

-

Insert brass pin contact - 1 - in mount.

-

Close securing lever on Crimping Pliers For Fiber-optic Cable VAS6223/2 - arrow -.

-

Slide fiber optic cable - 2 - into brass pin contact - 1 - as far as spring-loaded stop.

-

Continue sliding fiber optic cable in as far as fixed stop and close Crimping Pliers For Fiber-optic Cable VAS6223/2.

-

Open fiber optic cable pliers and remove cable with brass pin contact.

CAUTION:  Do not excessively bend or kink fiber optic cables. (min. bending radius 25 mm). 