Oxygen Sensor: Testing and Inspection
Oxygen Sensor Heaters, Checking

Oxygen Sensor Heaters, Checking

The following procedure is used to diagnose Oxygen Sensor (O2S) 1 (behind Three Way Catalytic Converter (TWC)) Heater (Z29) for Oxygen
Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) and Oxygen Sensor (O2S) 2 (behind Three Way Catalytic Converter (TWC))
Heater (Z30) for Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131).

‹› When servicing terminals in harness connector of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) use only gold-plated

terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› The Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) and Oxygen Sensor (O2S) 2 Behind Three Way Catalytic

Converter (TWC) (G131) fuse OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check

Start diagnosis

-

Disconnect the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector -  1 - or the Oxygen
Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector -  3 -.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) terminals 1 to 2 for resistance.

Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 7347 > < Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 7345