Leak Detection Pump: Testing and Inspection
With Generic Scan Tool

Leak Detection Pump (LDP) V144, Checking

Special tools, testers and auxiliary items required

-

Multimeter.

-

Wiring diagram.

Test requirements

-

The Leak Detection Pump (LDP) V144 fuse OK.

-

The ignition switched off.

NOTE:  The voltage for the Leak Detection Pump (LDP) -V144- is supplied by the Secondary Air Injection (AIR) Pump Relay J299.

Test procedure

-

Perform a preliminary check to verify the customers complaint.  See: Computers and Control Systems/Testing and Inspection/Initial Inspection
and Diagnostic Overview/Preliminary Check

Start diagnosis

-

Remove the right rear wheel housing liner.

-

Disconnect the Leak Detection Pump (LDP) V144 electrical harness connector - 4 -.

Checking internal resistance

-

Using a Multimeter, check the Leak Detection Pump (LDP) V144 for resistance as follows:

Leak Detection Pump (LDP) V144

Specified value

Electrical harness connector
terminals

1+3

640 to 720 ohms

2+3

15 to 17 ohms

If any of the specifications were not obtained:

-

Replace the Leak Detection Pump (LDP) -V144-.

If the specified values were obtained: 

With Generic Scan Tool|Page 7867 > < Evaporative Emission Control Canister|Service and Repair|Page 7861