audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 6631 > < Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 6629
Page 1
background image

Oxygen Sensor: Testing and Inspection
Heated Oxygen Sensors, Checking

Heated Oxygen Sensors, Checking

The following procedure is used to diagnose Oxygen Sensor (O2S) Heater (Z19) for Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor (O2S)
2 Heater (Z28) for Heated Oxygen Sensor (HO2S) 2 (G108).

‹› When servicing electrical harness connector terminals for the Heated Oxygen Sensors, use only gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹›  The Heated Oxygen Sensor (HO2S) (G39) and Heated Oxygen Sensor (HO2S) 2 (G108) fuses OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

-

Disconnect the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 2 - or the Heated Oxygen Sensor (HO2S) 2 (G108) electrical
harness connector- 4 -.

Checking internal resistance

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) terminals 3 to 4 for resistance.

Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 6631 > < Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 6629