audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 6635 > < Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 6633
Page 2
background image

Specified value: 1.0 to 20.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the faulty Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC). 

If the specification was obtained:

Checking voltage supply

Switch the ignition on.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) electrical harness connector terminal 1 to the
Engine Component Power Supply Relay (J757) terminal 2/87 for voltage.

Specified value: Battery voltage.

Switch the ignition off.

If the specification was not obtained:

-

Check the wiring for a short circuit to each other, Ground (GND) or an Open circuit.

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the specification was obtained:

Checking Ground (GND) activation

If the manufacturers test box is being used. Perform the following step.

-

Install the Test Box.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Replacing ] See: Computers and Control
Systems/Engine Control Module/Service and Repair/Engine Control Module, Replacing.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) electrical harness connector to the Engine
Control Module (ECM) (J623) electrical harness connector T94 for an open circuit.

Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 6635 > < Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 6633