Shift Solenoid: Testing and Inspection

Solenoid Valves in Valve Body, Checking

This procedure is used to diagnose all Solenoid Valves in the valve body.

Special tools, testers and auxiliary items required

‹› Multimeter

‹› Wiring diagram

Requirements

‹› The Solenoid Valve fuses OK.

‹› The battery voltage must be at least 12.5 Volts.

‹› All electrical consumers must be switched off.

‹› The parking brake must be engaged.

‹› The elector lever must be in the "P" position.

‹› The Ground (GND) connections to transmission must be OK.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

-

Disconnect the Solenoid Valve electrical harness connector - 2 -.

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

Repair any damage found to the electrical harness connector.