audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 3396 > < Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 3394
Page 1
background image

Oxygen Sensor: Service and Repair

Oxygen Sensors

Special tools, testers and auxiliary items required

‹› Ring spanner 7-piece set for oxygen sensor (3337)

Removing

-

Remove affected electrical connector from bracket on right strut tower and disconnect.

1. To Oxygen Sensor (O2S) behind Three Way Catalytic Converter (TWC) (G130)

2. To Heated Oxygen Sensor (HO2S) (G39)

3. To Oxygen Sensor (O2S) 2 behind Three Way Catalytic Converter (TWC) (G131)

4. To Heated Oxygen Sensor (HO2S) 2 (G108)

-

Free up electrical wiring to oxygen sensor.

-

Remove affected oxygen sensor with open end wrench (3337/1) and (3337/2):

1. Oxygen Sensor (O2S) 2 behind Three Way Catalytic Converter (TWC) (G131)

2. Heated Oxygen Sensor (HO2S) 2 (G108)

Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 3396 > < Heated Oxygen Sensors and Oxygen Sensor Regulation before Catalytic Converter, Checking|Page 3394