audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fluid Pressure Sensor/Switch, A/T|Testing and Inspection|Page 9074 > < Fluid Pan, A/T|Specifications|Page 9070
Page 1
background image

Fluid Pressure Sensor/Switch: Testing and Inspection

Senders for Hydraulic Pressure, Checking

‹› This procedure is used to diagnose Automatic Transmission Hydraulic Pressure Sensor 1 (G193) and Automatic Transmission Hydraulic Pressure

Sensor 2 (G194)

Special tools, testers and auxiliary items required

‹› Multimeter

‹› Wiring diagram

Requirements

‹› The Automatic Transmission Hydraulic Pressure Sensor 1 (G193) fuse OK.

‹› The Automatic Transmission Hydraulic Pressure Sensor 2 (G194) fuse OK.

‹› The battery voltage must be at least 12.5 Volts.

‹› All electrical consumers must be switched off.

‹› The parking brake must be engaged.

‹› The elector lever must be in the "P" position.

‹› The Ground (GND) connections to transmission must be OK.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Powertrain Management/Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

-

Disconnect the Automatic Transmission Hydraulic Pressure Sensor electrical harness connector - 3 -.

Fluid Pressure Sensor/Switch, A/T|Testing and Inspection|Page 9074 > < Fluid Pan, A/T|Specifications|Page 9070