Control Module HVAC: Service and Repair
Fresh Air Blower Control Module

Fresh Air Blower Control Module

Removing

-

Switch off ignition.

-

Remove the air intake unit, refer to => [ Air Intake Unit ] See: Heating and Air Conditioning/Air Duct/Service and Repair/Air Intake Unit.

-

Remove the air intake unit upper cover, refer to => [ Air Intake Unit Upper Cover ] See: Heating and Air Conditioning/Air Duct/Service and
Repair/Air Intake Unit Upper Cover.

-

Disconnect the electrical connectors - A - and -  B -.

-

Remove bolts - C -.

CAUTION!
The heat sink on the fresh air blower control module may be hot.

-

Remove Fresh Air Blower Control Module (J126) - D -.

Installing

To installed, perform the steps done during removal in reverse order. Note the following:

-

Install the fresh air blower control module - D -. 

-

Tighten the bolts - C - by hand (10 Ncm).

-

Connect the electrical connectors - A - (to the Fresh Air Blower (V2)) and - B -.

-

Before installing the air intake unit upper cover, make sure the electrical connectors - A - and - B - are seated correctly and the wiring harness is
routed correctly.

-

Install the air intake unit, refer to => [ Air Intake Unit ] See: Heating and Air Conditioning/Air Duct/Service and Repair/Air Intake Unit.

After finishing the repairs, perform the following work on the Climatronic Control Module (J255) using Vehicle diagnosis, testing and information
system VAS 5051/ in the "Guided Fault Finding" function: 

-

Check the DTC memory and erase any malfunctions shown.

-

Perform the basic setting.

-

Perform the output diagnostic test mode.