audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Flow Flap Motor V71, Removing And Installing|Page 7865 > < Air Flow Flap Motor V71, Removing And Installing|Page 7863
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Recirculation Flap Motor V113, Removing And Installing

Recirculation Flap Motor V113, Removing And Installing

Removing

-

Remove glove compartment.

-

Disconnect connector - A -.

-

Remove bolts - B -.

-

Pull connecting element - C - of Recirculation Flap Motor V113 out of recirculated-air flap shaft - D -.

Installing

NOTE:  The control motor connecting element is color-coded; for the Recirculation Flap Motor V113 it is blue

Reinstall all parts removed in reverse order, paying attention to the following:

-

Lay wiring harness such that it cannot come into contact with moving components (e.g. control motor lever).

-

Check and erase DTC memory; perform basic setting.

NOTE:  Operation of the control motor can be checked as follows: Connect the two contacts "5" and "6" in the control motor connector to a 12 V
DC source. The control motor moves as far as the stop in one direction. Interchanging positive and negative reverses direction. Use adapter for this
purpose.