audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Leak Detection Pump, Checking, Vehicles With MPI Engine|Page 3964 > < Leak Detection Pump, Checking, Vehicles With MPI Engine|Page 3962
Page 4
background image

If specifications are not obtained:

-

Replace the Leak Detection Pump (LDP) (V144). Refer to => [ Leak Detection Pump ] See: Service and Repair.

If specified values are achieved:

-

Check voltage supply of leak detection pump. 

Checking voltage supply

‹› Voltage is supplied to the leak detection pump via the Fuel Pump (FP) Relay (J17).

Test Conditions

‹› Fuse for leak detection pump OK

-

Connect Voltage Tester (V.A.G 1527B) as follows:

-

Briefly operate starter.

‹› LED must light up.

If LED does not light up:

Leak Detection Pump, Checking, Vehicles With MPI Engine|Page 3964 > < Leak Detection Pump, Checking, Vehicles With MPI Engine|Page 3962