Test for open circuit in wiring from Secondary Air Injection (AIR) Pump Relay -J299- (located in 3-way relay carrier in electronics box in
plenum chamber) to fuel pump relay via fuse -S234- (in fuse box, socket 34). Refer to wiring diagram.

-

Eliminate open circuit in wiring (refer to wiring diagram).

Testing activation of secondary air pump relay 

-

Switch ignition off.

-

Disconnect secondary air pump relay.

Part 1

Part 2

-

Connect voltage tester VAG 1527 B as follows:
^

Vehicle diagnostic, testing and information system VAS 5051 is connected; vehicle system "01 - Engine electronics" is selected. Ignition must
be switched on.

Display on VAS 5051:
-

Select diagnosis function "03 - Final control diagnosis" from menu -1-

-

Press the (arrow) button repeatedly until following display appears: