using compressed air and nitrogen. Refrigerant R134a - Servicing
-
Insert in bracket - D -.
-
Engage bracket - D - with lug - B -.
-
Insert and tighten bolts - A - (tightening torque 8 Nm).
-
Replace O-rings - D -.
-
Turn the accumulator such that the two refrigerant lines - B - and - C - can be inserted without strain in the accumulator. In doing so, pay attention
to correct assignment of connections.
-
Use bolt - A - to attach refrigerant line to accumulator (tightening torque 25 Nm). Use oil filter strap for example to secure accumulator to prevent
it turning.
-
Tighten bolt - C - (tightening torque 8 Nm).
-
Reinstall remaining components removed.
-
Discharge and recharge refrigerant circuit. Refrigerant R134a - Servicing.