background image

-

Briefly operate starter.
^

LED must light

If LED does not light:
-

Use wiring diagram to check for open circuit in wiring from contact 1 of connector via fuse to fuel pump relay.

-

Use wiring diagram to eliminate open circuit in wiring.

If LED lights:

Checking actuation

-

Connect voltage tester V.A.G 1527 B between contacts 1 and 2.

-

Vehicle diagnostic, testing and information system VAS 5051 connected; vehicle self-diagnosis and vehicle system "01.Engine electronics"
selected. Ignition must be on.

Indicated on VAS 5051:
-

From list -1- select diagnostic function "03. Final control diagnosis".

-

Keep touching - key until Secondary AIR solenoid valve -N112- is actuated.
^

LED must flash

-

Terminate function "0.3 - Final control diagnosis" by touching - key.

If LED does not flash or if it is permanently lit:

-

Connect test box V.A.G 1598/31 to wiring harness connectors. Actual engine control module is not to be connected. Connect Ground clip of test
box to Ground (not shown in Fig.).

CAUTION:  Always observe the test conditions and select the required measuring range before connecting test leads to prevent damaging
electronic components.