Secondary Air Injection (AIR) Pump Relay at position 2 (in 3-pin relay carrier, E-box plenum chamber) must engage and Secondary Air
Injection (AIR) Pump Motor -V101- must run

-

Switch ignition off.

A. Secondary Air Injection (AIR) Pump Motor runs.

-

Check voltage supply of the Secondary Air Injection (AIR) pump relay

-

Check activation of the Secondary Air Injection (AIR) pump relay

B. Secondary Air Injection (AIR) Pump Motor does not run.

-

Check voltage supply of the Secondary Air Injection (AIR) pump motor

Checking voltage supply of Secondary Air Injection (AIR) pump relay

-

Remove Secondary Air Injection (AIR) pump relay from position 2 in 3-pin relay carrier, E-box, plenum chamber.

-

Connect multimeter for voltage measurement as follows.

3-pin relay carrier, E-box plenum chamber, position 2 Terminal

Measure to

8

Engine Ground (GND)

Specified value: approx. battery voltage

If specified value is not obtained:

-

Check wire connection from B+ (terminal 30) via Fuse for secondary air pump -S130- to Secondary Air Injection (AIR) Pump Relay -J299- (in
3-pin relay carrier, E-Box, plenum chamber, position 2) for open circuit according to wiring diagram.
-

Specified value: Wire resistance max 1.5 Ohms