Fuel Injector: Testing and Inspection
Leak Check

Fuel Injection Volume, Fuel Injector Leakage And Spray Pattern Of Injectors, Checking

Checking For Leaks

-

Bridge sockets 1 and 65 on the test box using test leads from VAG1594 A connector test kit. (This creates an Ground (GND) connection to one
side of the fuel pump relay coil.)

NOTE:

Once the socket are bridged the fuel pump runs continuously, even if the engine is not running. This is because the fuel pump relay receives its positive
voltage supply via the central electrics. The negative voltage supply for the fuel pump relay comes via the cable bridge on the test box.

WARNING!
Fire hazard. DO NOT smoke or work near heaters or have anything in the area that can ignite fuel!

-

Check injectors fuel for leaks (visual check). When fuel pump is running, only 1 or 2 drops should escape per minute from each injector.

-

If fuel loss is greater, switch off fuel pump (remove bridge) and replace faulty injector.

Checking injection quantity

-

Place fuel injector which is to be tested into measuring glass from injection quantity tester VAG1602.

-

Connect one fuel injector terminal to engine Ground (GND) using test cable and crocodile clamp from VAG1594 connector test kit.

-

Connect second fuel injector terminal to B+ using remote control VAG1348/3 A, adapter cable VAG1348/3-2 and auxiliary cable.

WARNING!
Make sure test box is inside of passenger compartment

-

Bridge sockets 1 and 65 on the test box using test leads from VAG1594 A connector test kit. (This creates an Ground (GND) connection to one

Fuel Injector Volume, Leakage and Spray Pattern Check|Page 6326 > < Fuel Injector Volume, Leakage and Spray Pattern Check|Page 6324