Battery: Component Tests and General Diagnostics
Specific Gravity, Checking

Specific Gravity, Checking

Special tools, test equipment and auxiliary items

-

Commercially available hydrometer

-

Shop towel

CAUTION:

-

When working with battery acid, make sure to follow all "Warnings and safety precautions for lead-acid batteries." Wear suitable
protective clothing and eye protection.

-

When disposing of batteries, always comply with applicable Federal, State and local laws regarding the disposal of batteries and sulfuric
acid.

NOTE:

-

In order to better determine the overall condition of a battery, always perform a specific gravity test in conjunction with the load test.

-

The temperature of the electrolyte must be at least 10 degrees C (50 degrees F).

The specific gravity can be tested immediately after charging the battery.

Use the following procedure to test the specific gravity in all of the battery cells:

-

Switch ignition off.

-

Remove all cell caps.

-

Immerse tip of hydrometer into battery cell and draw out enough electrolyte to allow indicator to float freely.

The higher the specific gravity of the drawn electrolyte, the higher the indicator will float.

The specific gravity of the electrolyte can be read in kg/cu.dm on the hydrometer scale.

-

Compare measured value indicated on hydrometer to values indicated in table below:

State of charge in normal climate zones

Specific gravity in kg/cu.dm

Discharged

1.12

Half charged

1.20

Good charge

1.28

In normal climate zones, the specific gravity must be at least 1.24 kg/cu.dm.

-

If specific gravity is too low: charge battery.

-

After charging battery, repeat specific gravity test.

Electrolyte Level, Checking|Page 5057 > < Electrolyte Level, Checking|Page 5055