Seal connection using a plug that fits.

-

Remove coolant expansion tank - arrow -.

-

Disconnect electrical wire to Engine Coolant Level (ECL) Warning Switch (F66) at bottom on expansion tank and set aside coolant expansion
tank with coolant hose - 1 - connected. 

-

Remove electrical harness connectors - 1 to 4 - from bracket at left of bulkhead.

-

Disconnect connectors - 1 - and - 4 -. 

-

Remove bracket from bulkhead.

-

Remove heat insulation sleeve on wiring harness and lay open wiring harness.

-

Free up oxygen sensor wires downward.

-

Remove left front wheel.

-

Remove quick-release fasteners - 1 -, remove screws -  2 - and remove noise insulation.