Control Module: Description and Operation
Control  Module

PURPOSE    

The Transmission Control Module (TCM) 01F/01K controls and monitors the operation of the automatic transmission. The TCM records any faults it
detects and will go into "Fail Safe Mode" to insure operation and safety of the transmission if a critical fault occurs.

OPERATION

The TCM collects information from various sensors and other control modules such as the M.P.I. Engine Control Module (ECM) for engine
management information and the ABS Control Module for information about road speed. After evaluating this information, the TCM generates output
signals to the actuators.

The TCM also generates output signals to the M.P.I. ECM (to retard ignition timing during upshifts and downshifts) and the A/C Control Head (to
switch off the A/C compressor clutch under full throttle acceleration.)

The TCM monitors all inputs and outputs to detect any faults or values that are outside of normal operating range. It is equipped with a permanent
fault memory and self-diagnosis capabilities.

If the Transmission Control Module detects  a critical fault, or the TCM fails, the transmission will go into one of two emergency running modes. The
Emergency Running Mode level depends on the nature of the failure.

CONSTRUCTION

Two important relays are integrated in the Transmission Control Module:

^  The Solenoid Valve Power Supply Relay
^  Cruise Control Power Supply Relay
The Solenoid Valve Power Supply Relay supplies voltage to shift solenoids N88, N89, N9O and ATF pressure modulating valve N91. The Cruise
Control Power Supply Relay supplies voltage to the Cruise Control ON/OFF switch after the vehicle has reached a speed of 22 MPH.

Note:

Neither of these relays can be serviced. Should either relay malfunction, the TCM must be replaced. Both relays are checked during Output Check
Diagnosis when using the V.A.G 1551.