S5 Quattro Coupe V8-4.2L (CAUA) (2009)
Rear Vision Camera: Testing and Inspection
Rearview Camera System, Calibrating
After performing service work on the vehicle, it may be necessary to calibrate the rear view camera system anew. In detail, this is the case after:
‹› Rear View Camera (R189), Removing and Installing
‹› Rear View Camera System Control Module (J772), Removing and Installing
‹› Collision repairs on rear lid
‹› Wheel Alignment
‹› Rear Axle Repairs
Preparations before starting work
Special tools, testers and auxiliary items required
‹› Vehicle Diagnostic, Testing and Information System (VAS 5051)
‹› Calibration Device (VAS 6350)
‹› Spacing Laser (Vas 6350/2)
Vehicle must stand on a firm and level surface to perform the calibration. No persons may be in the vehicle interior during the measurement. Vehicle
must not be moved during the measurement, opening and closing of vehicle doors is to be avoided. The rear lid is closed.
-
Connect Vehicle diagnosis, testing and information system VAS 5051.
-
Bring the Steering Angle Sensor (G85) into 0-position (wheels straight ahead).
Overview of assembled calibration equipment