audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Condenser HVAC > < Compressor Pulley|Page 6300
Page 2
background image

-

Tighten the drive plate - C - to 30 Nm by turning it in the direction of arrow - E - using a conventional band wrench (with webbed band); counter
hold the compressor shaft - A - using a counter holder - B - on the compressor shaft - A -. 

‹› Depending on compressor version (compressor shaft varies), an open end wrench or e.g. a Socket Wrench (T10001/10) from Shock Absorber Set

(T10001) or Retainer (3079) must be used to counter hold.