audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Disconnecting and Connecting Refrigerant Lines From Compressor|Page 6436 > < Disconnecting and Connecting Refrigerant Lines From Compressor|Page 6434
Page 3
background image

-

Check the connections in the expansion valve - B - and on the refrigerant line - D - for damage.

-

Replace the quick acting coupling connectors on the refrigerant line with inner heat exchanger. Refer to => [ Disconnecting and Connecting
Refrigerant Lines, Quick-Release Couplings ]  See: Compressor HVAC/Service and Repair/Disconnecting and Connecting Refrigerant Lines,
Quick-Release Couplings

-

Replace the O-ring seals - A - and - C - version.

‹› Note the installation instructions for O-ring seals. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Description and Operation/Refrigerant

Circuit.

-

Coat O-ring seals lightly with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Description and
Operation/Refrigerant Circuit.

-

Make sure the O-ring seals fit properly in the refrigerant line connection grooves and on the refrigerant line - D -.

-

Tighten the bolts - E - for the refrigerant line - D - with inner heat exchanger.

‹› Tightening specification for the bolts - E -: 10 Nm. 

-

Tighten the nut - C - for the refrigerant line - B -.

Disconnecting and Connecting Refrigerant Lines From Compressor|Page 6436 > < Disconnecting and Connecting Refrigerant Lines From Compressor|Page 6434