Using a Multimeter , check the Fuel Metering Valve 2 (N402) terminals 1 to 2 for resistance 

Specified value: 450 to 1000 ohms.

If the specified value was not obtained:

-

Replace the Fuel Metering Valve 2 (N402).

If the specified value was obtained:

Checking voltage

Crank the engine.

-

Using a Multimeter, check the Fuel Metering Valve 2 (N402) electrical harness connector terminal 1 to Ground (GND) for voltage.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the wiring from the Fuel Metering Valve 2 (N402) electrical harness connector terminal 1 to the Fuse (on fuse/relay panel) (S5) for an open
circuit or a short circuit to Ground (GND).

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the wiring connection.