Accumulator HVAC: Service and Repair

Removing

-

Discharge A/C refrigerant system See: Service and Repair 

-

Remove front bumper as complete unit.  

-

Remove bolts -A-.

-

Disconnect refrigerant line -B-. Tightening torque: 40 Nm (30 ft. lb)

-

Remove nuts -D-.

-

Remove accumulator together with bracket.

-

Disconnect refrigerant line -B-.
Tightening torque: 40 Nm (30 ft. lb)

NOTE:  Replace both O-rings (17.2 mm x 1.8 mm).

-

Seal off all open connections.

 
Installing

Install refrigerant lines free of stress and make sure there is sufficient clearance between lines and other components.