S6 V8-4.2L (BBD) (2004)
-
Select function "4" in button field -2- For Adaptation channel 41" and press Q button to confirm input.
Display on VAS5051:
1
-
Channel 41 read and test
2
-
Actual value In spec. in 1 Days
3
-
Keypad - only direct input via the keypad is possible
4
-
The sliding bar is positioned on the current adaptation value, e.g. 110 Time in days since last service is displayed (here For example 110
represents 110 days)
NOTE:
-
Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.
-
When replacing instrument cluster, observe.
-
Change adaptation value via direct input See "B - Change adaptation value via direct input".
-
Enter 5-digit adaptation value. Insert zeros in front.
Example:
Desired input value: For example 200 days
Keypad input: 00200
Display on VAS5051 after performed adaptation: