S6 V8-4.2L (BBD) (2004)
-
Select function "44" in button field -2- For "Adaptation channel 44" and press Q button to confirm input.
Display on VAS5051:
1
-
Channel 44 read and test
2
-
Maximum value In spec. in 1 Days
3
-
Keypad - only direct input via the keypad is possible
4
-
The sliding bar is positioned on the current adaptation value, e.g. 365
The display indicates the maximum time interval in days to the next service (here For example, 365 represents 365 days).
NOTE:
-
The currently valid specifications can be found in the "Maintenance" book.
-
Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.
-
Change adaptation value via direct input = "B - Change adaptation value via direct input".
-
Enter 5-digit adaptation value. Insert zeros in front.
Example:
Specification: For example 365 days
Keypad input: 00365
NOTE: The "Save" button does not appear if an incorrect value was entered!
Display on VAS5051 after performed adaptation: