audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Manufacturer's Scan Tool|Page 6122 > < How to Find Wiring Diagrams|Page 6118
Page 1
background image

Ignition Coil: Testing and Inspection
With Manufacturer's Scan Tool

Ignition Coils With Power Output Stage,  Checking

NOTE:  The ignition coil and the output stage are combined in a common component.

Checking Ground supply of output stage

-

Disconnect 4-pin connector from relevant ignition coil.

-

Check Ground connection from socket 2 on 4-pin connector to body Ground for open circuit or short to positive.

-

Correct any open/short circuit as necessary.

If the Ground connection is OK:

-

Check actuation of output stages.

Checking actuation of power output stages

-

Disconnect connectors from all eight injectors.

NOTE:  It is important to ensure that no fuel is injected during the test, as this would damage the catalytic converter. Therefore, the connectors on the
injectors must be disconnected.

-

Disconnect 4-pin connector from relevant ignition coil.

-

Connect VAG 1527 diode test lamp to following contacts on power output stage connector:

-

Operate starter for a few seconds.

4-pin connector of relevant ignition coil 
at wiring harness, socket

Specified value

3 + 2

Diode test lamp must flash (brief impulse)

If the specified values are not obtained:

-

Switch ignition off.

-

Connect test box VAG 1598/31 to wiring harness for engine control module; do not connect engine control module. See: Computers and Control

With Manufacturer's Scan Tool|Page 6122 > < How to Find Wiring Diagrams|Page 6118