S6 Quattro Sedan V10-5.2L (BXA) (2007)
After-Run Coolant Pump: Service and Repair
After-Run Coolant Pump V51, Removing and Installing
After-Run Coolant Pump V51, removing and installing
Special tools, testers and auxiliary items required
^
Hose clamps up to 25 mm dia. 3094
^
Drip tray for workshop crane VAS 6208 or V.A.G. 1306
^
Hose clamp pliers V.A.G. 1921
Removing
CAUTION!
Cover cap of coolant expansion tank with rag and open carefully, as hot steam or hot coolant may escape when opening.
-
Open cap of coolant expansion tank.
-
Remove stabilizer bar.
-
Clamp off coolant hoses - 2 - and - 3 - with Hose Clamps 3094.
-
Disconnect electrical connector - 1 -.