audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Cleaner Housing > < Air/Fuel Mixture|Specifications
Page 1
background image

Air/Fuel Mixture: Adjustments

NOTE: Air/Fuel mixture is electronically controlled by the Motronic ECM and cannot be adjusted. There are no adjustment screws, air/fuel mixture

can only be checked.

AIR/FUEL MIXTURE CHECKING

PRE-CHECK REQUIREMENTS

1.

Engine oil temperature at 185°F (85°C) minimum (operating temp.)

2.

Throttle valve in idle position

3.

Closed throttle position switch operating properly

4.

All electrical consumers turned OFF

5.

A/C turned OFF

6.

Fuel pressure gauge NOT connected

7.

Radiator fan MUST NOT run while taking measurements

8.

Crankcase breather connected

9.

NO diagnostic trouble codes stored in ECM fault memory

AIR/FUEL MIXTURE CHECKING PROCEDURE

CO Tap 20v

1.

Connect CO tester to CO tap (near turbo wastegate and Heated Oxygen Sensor) using adaptor 1363/3 and connecting hose 6006-0019 or
equivalent.

2.

START engine and let idle, CO content must be:

0.5 to 0.9%

3.

IF NOT

^ Ensure that all spark plugs are functioning properly

NOTE: Failure of one spark plug increases CO content by approximately 1.5%.

4.

IF spark plugs are OK but CO specification still NOT obtained:

^ Recall ECM fault memory and perform Output Diagnostic Test Mode, then retest.

Air Cleaner Housing > < Air/Fuel Mixture|Specifications