S8 Quattro Sedan V10-5.2L (BSM) (2009)
Checking internal resistance
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) 4 (G286) terminals 3 to 4 for resistance.
Specified value: 2.5 to 10.0 ohms (at approx. 20 °C)
If the specification was not obtained:
-
Replace Heated Oxygen Sensor (HO2S) 4 (G286).
If the specification was obtained:
Checking voltage supply
Crank the engine.
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) 4 (G286) electrical harness connector terminal 4 to Ground (GND) for voltage.