audi Workshop Repair Guides

Audi TT L4 Turbo Workshop Service and Repair Manuals

Intercooler > < Not Available For Manufacturer's Scan Tool
Page 1
background image

Exhaust Bypass Valve: Testing and Inspection
With Generic Scan Tool

Recirculating Valve For Turbocharger, Checking

NOTE:  Valve opens between connection to intake manifold and connection to deceleration shut-off valve with no voltage. Connection to vacuum
reservoir is closed.

Test sequence

-

Switch ignition off.

-

Disconnect connector from Recirculating valve for turbocharger -N249-.

-

Measure resistance between terminals of valve.
Specified value: 27...30 Ohm

If specified value is not obtained:

-

Replace Recirculating valve for turbocharger -N249-.

If specified values are obtained:

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring
Test

-

Check wire between test box socket 105+2-pin connector terminal 2 for open circuit according to wiring diagram.
Wire resistance: max: 1.5 Ohm

-

Also check the wire for short circuit to B+ and Ground (GND).

If no malfunctions are found in wire:

-

Check wire between 2-pin connector terminal 1 and the Fuel Pump (FP) Relay -J17- for open circuit according to wiring diagram.
Wire resistance: max: 1.5 Ohm

If no malfunctions are found in wires:

-

Replace Engine Control Module (ECM).

Intercooler > < Not Available For Manufacturer's Scan Tool