audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Power and Ground Distribution > < All Technical Service Bulletins for Wiring Harness:|971015|Page 8956
Page 2
background image

-

Using crimp connectors on the ends of the wires, crimp on both sides with crimping pliers.
-

Do not crimp the insulation on the wires

-

Make sure that the correct crimping slot is used (red color code for 0.5 sq.mm wires)

-

After crimping the connector, seal it by shrinking with a hot air blower.
-

Heat the crimp connector from the center outward until it is completely sealed and the adhesive comes out. 

-

Set the hot air blower to the correct temperature (refer to operating manual).

-

When heating the connector, take care not to damage any other wiring, plastic parts or insulating material with the hot nozzle.

-

If the wire was originally taped, wrap it again with yellow insulating tape. If necessary, secure the wiring with new cable ties.