audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor Before Catalytic Converter, Checking|Page 3182 > < Heated Oxygen Sensor Before Catalytic Converter, Checking|Page 3180
Page 7
background image

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Replacing ] See: Engine Control Module/Testing and
Inspection/Engine Control Module.

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) 2 (G108) electrical harness connector to the Engine Control Module (ECM) (J623)
electrical harness connector T81 for resistance.

Specified value: 1.5 ohms max.

If the specification was not obtained:

-

Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring and if the voltage supply was OK:

-

Erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] See: Testing and Inspection/Scan Tool Testing and
Procedures/Diagnostic Mode 04 - Erase DTC Memory

-

Perform a road test to verify repair.

If the DTC does not return:

Repair complete, Generate readiness code. Refer to => [ Readiness Code Description ] See: Testing and Inspection/Scan Tool Testing and
Procedures/Diagnostic Mode 09 - Read Vehicle Information. 

-

End diagnosis.

If the DTC does return and no malfunction is detected in the wiring and the voltage supply was OK:

-

Replace the Engine Control Module (ECM) (J623 ). Refer to => [ Engine Control Module, Replacing ] See: Engine Control Module/Testing and
Inspection/Engine Control Module.

-

Assembly is performed in the reverse of the removal.

Final procedures

After repair work, the following work steps must be performed in the following sequence: