audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Intake Manifold Flaps, Checking Vacuum Actuator|Page 3585 > < Intake Manifold Flaps, Checking Vacuum Actuator
Page 2
background image

‹› Ignore - 1 -, - 2 - and - arrows  -.

-

Connect Hand Vacuum Pump (VAS 6213) to vacuum actuator connector as shown in illustration.

-

Generate vacuum using hand vacuum pump.

-

Observe linkage on vacuum actuator when doing so:

‹› Linkage must move - arrow -.

-

Vent hand vacuum pump.

Intake Manifold Flaps, Checking Vacuum Actuator|Page 3585 > < Intake Manifold Flaps, Checking Vacuum Actuator