TT Quattro Roadster L4-1.8L Turbo (AMU) (2002)
![background image](/audi/tt_quattro_roadster/l4-1.8l_turbo_(amu)/Page-1337003.png)
-
Connect multimeter between terminal 3 and 4 of connector for resistance measurement.
All models
Range A shows the resistance values for the temperature range from 0 to 50 degree C, and range B shows the values for the temperature range from
50-100 degree C.
Read-out examples:
-
30 degree C corresponds to a resistance of 1500 to 2000 ohms
-
80 degree C corresponds to a resistance of 275 to 375 ohms
If specified value is not obtained:
-
Replace coolant temperature sensor.
If specified value is obtained:
-
Connect VAG1598/31 test box at wiring harness to ECM, do not connect ECM. See: Computers and Control Systems/Testing and Inspection/Scan
Tool Testing and Procedures/Scan Tool Testing/Scan Tool Connecting and Initial Checks/Wiring and Component Testing Using VAG1598/31
Test Box
Coolant temperature sensor with square connector:
-
Check the following wire connections for open circuit and short circuit to Ground (GND) and B+: