audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Convertible Top Pump|Service and Repair|Page 11903 > < Convertible Top Hydraulic Cylinder|Service and Repair
Page 1
background image

Convertible Top Pump: Service and Repair

Hydraulic Pump, Removing And Installing

1

-

Noise chamber

2

-

Hex bolts
-

8 Nm

3

-

Solenoid valve

CAUTION:  Solenoid valves must only be threaded into the hydraulic pump in activated (energized state) using output Diagnostic
Test Mode (DTM).

4

-

Oil reservoir
-

Mounting bolts must only be tightened to 2 Nm after replacing oil reservoir.