Air Bypass Valve: Testing and Inspection
Deceleration Shut-Off Valve, Checking

Deceleration Shut-off Valve, Checking

Recommended special tools and equipment e.g.:

-

VAG1390 hand vacuum pump

Test requirement

-

Performance deficiency or tip-in shocks

Test sequence

NOTE:  The deceleration shut-off valve is located in front of the turbocharger. It is opened by vacuum during deceleration and at idle.

-

Attach VAG1390 vacuum pump to recirculation valve.

-

Operate vacuum pump.
-

Recirculation valve must open (arrow)

-

After approx. 30 seconds, operate vent valve on vacuum pump.
-

Recirculation valve must close (arrow)

If recirculation valve does not open or close or valve plate does not seal correctly when valve is closed:

-

Replace recirculation valve. Secure connections of recirculation valve using screw clamps.