After-Run Coolant Pump: Service and Repair
After-Run Coolant Pump

After-Run Coolant Pump

Special tools, testers and auxiliary items required

‹› Hose Clamps Up To 25 Mm Diameter (3094)

Removing

-

Remove front noise insulation. Refer to - 1 -

-

Disconnect electrical connector - 1 -.

‹› Lay a cloth below to catch escaping coolant.

-

Clamp off coolant hoses - arrow - with hose clamps hose clamps up to 25 mm diameter (3094) and remove. 

-

Remove bolt - 3 - and the after-run coolant pump. 

‹› Ignore - 2 and 4 -.

Installing

‹› For tightening specifications, refer to => [ After-Run Coolant Pump Assembly Overview ] See: After-Run Coolant Pump Assembly Overview.