audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Leak Detection Pump, Checking|Page 2606 > < Leak Detection Pump, Checking
Page 2
background image

If any of the specifications are not obtained:

-

Replace the Leak Detection Pump (LDP) (-V144- ).

If the specified values are obtained:

Checking voltage supply

‹› The voltage for the Leak Detection Pump (LDP) (-V144- ) is supplied via the Fuse 7 (on fuse panel B) ( SB7).

-

Check the Leak Detection Pump (LDP) (-V144-) for voltage.

-

Using a multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 and ground for voltage.

-

Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

Leak Detection Pump, Checking|Page 2606 > < Leak Detection Pump, Checking