audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Intercooler|Service and Repair > < Intercooler|Testing and Inspection|Page 2858
Page 3
background image

‹› If there is water in the viewing glass, drain it through the drain plug - 6 -.

-

Open valve - 3 -.

CAUTION!
Pressure must not exceed 0.5 bar! Damage could result if the pressure is set too high.

-

Set the pressure to 0.5 bar using the pressure control valve -  2 -.

-

Open the valve - 4 - and wait until the test circuit is filled. Regulate the pressure to 0.5 bar again if necessary.

-

Listen, feel and use commercially available leak detection spray or the ultrasonic tester (V.A.G 1842) to check the charge air system for leaks.

‹› A small quantity of air dissipates via valves in engine. A pressure retention test is not possible for this reason.

‹› For information on using the ultrasonic tester (V.A.G 1842 ), refer to the => Operating Instructions.

‹› Before removing adapter, discharge pressure in testing circuit by pulling off coupling from adapter (V.A.G 1687/5).

‹› The hose supports, air guide pipes and hoses must be free of oil and grease before installing.

-

Follow the instructions for installing the air guide pipes and hoses with connector couplings. Refer to => [ Air Guide Pipes and Hoses with
Connector Coupling ] See: Service and Repair/Air Guide Pipes and Hoses with Connector Coupling. 

-

Install noise insulation.

Intercooler|Service and Repair > < Intercooler|Testing and Inspection|Page 2858